HTML Content Started Here
************************************************************
--%>
Category : RF Measurement Analyzers

|
|
Mfg. Name |
Mfg. Part# |
Product |
Unit Price |
Add To Cart |
| |
| |
HP / Agilent
|
53310A
|
HP / Agilent 53310A Modulation Domain Analyzer
|
Contact Sales
|
|
|
Characterizes modulation and jitter with built-in analysis and automated measurements to 200 MHz, to 2.5 GHz with option 030. Single-shot frequency resolution to 10 digits, time-interval resolution to 200 ps.The 53310A is an easy-to-operate, affordable modulation domain analyzer with an intuitive data display that gives you a direct view of jitter or modulation. Parameters such as peak-to-peak deviation, carrier frequency, and modulation rate are quickly and automatically displayed. Built-in analysis, including automated mean, standard deviation, and probability functions, provides detailed characterization of jitter.In much the same way an oscilloscope provides insight into the dynamics of changing voltage, the 53310A provides insight into changes in frequency or time-interval measurements. You save time reviewing designs and locating problems. Use the 53310A to study frequency drift in electronic equipment; characterize jitter of digital communications systems, peripherals, and mechanical systems; determine frequency hopping performance of an agile transmitter, or measure cellular phone switching from cell to cell |
| |
| |
HP / Agilent
|
5372A
|
HP / Agilent 5372A Frequency & Time Interval Analyzer
|
Contact Sales
|
|
|
125 mHz to 500 MHz. Characterize frequency, phase, and time-interval versus time. -4.0 to +4.0 second time interval range. 10 digit per second frequency resolution, HP-IB |
| |
| |
HP / Agilent
|
5373A
|
HP / Agilent 5373A Modulation Domain Pulse Analyzer
|
Contact Sales
|
|
|
125 mHz to 500 MHz with channels A and B. Fast time-interval histograms, pulsed measurements, and envelope measurements. HP-IB |
| |
| |
HP / Agilent
|
8901A
|
HP / Agilent 8901A Modulation Analyzer
|
Contact Sales
|
|
|
Combines the capabilities of several RF instruments to give complete, accurate characterization of modulated signals in the 150 kHz to 1300 MHz frequency range. It very accurately measures modulation and recovers the modulation signal, determines RF frequency and measures RF power |
| |
| |
HP / Agilent
|
8901B
|
HP / Agilent 8901B Modulation Analyzer
|
Contact Sales
|
|
|
Like the 8901A, the 8901B modulation analyzer combines the capabilities of several RF instruments to give complete, accurate characterization of modulated signals in the 150 kHz to 1300 MHz frequency range. It very accurately measures modulation and recovers the modulation signal, determines RF frequency and meaures RF power. The major additional capabilities of the 8901B are its improved power-meter accuracy, its ability to make adjacent-channel power measurements or carrier-noise measurements (with Options 030 through 037), and its ability to count audio frequencies and measure distortion on 400 Hz and 1 kHz signals |
| |
| |
HP / Agilent
|
8981B
|
HP / Agilent 8981B Vector Modulation Analyzer
|
Contact Sales
|
|
|
Displays phase and amplitude modulation vs. time. Analyzes analog I and Q signals, DC to 350 MHz. 50 to 200 MHz modulated IF input range. HP-IB |
| |
| |
HP / Agilent
|
8990A
|
HP / Agilent 8990A Peak Power Analyzer
|
Contact Sales
|
|
|
Provides complete and accurate characterization of complex pulsed signals. Performs seven automatic timing measurements (rise time, fall time, pulse width, PRI, PRF, duty cycle, and delay) and five automatic power measurement (peak power, average power, pulse top/base amplitude, and overshoot) with push-button ease. Offers two sensor channels plus two external triggering/oscilloscope channels, allowing the simultaneous measurement of modulating signals and detector power envelopes. Dynamic range -32 dBm to +20 dBm, minimum pulse width 10 ns, rise time 5 ns |
| |
| |
HP / Agilent
|
8992A
|
HP / Agilent 8992A Digital Video Power Analyzer
|
Contact Sales
|
|
|
Analyze digital video and digital audio broadcast power. Two power channels with dynamic range of -32 dBm to +20 dBm, minimum pulse width 10 ns, rise time 5 ns. Performs seven automatic timing measurements and five automatic power measurements. Features two oscilloscope channels permitting simultaneous measurements on modulated and detected waveforms. 20 MHz to 40 GHz (sensor dependent) Uses 84812A, 84813A, 84814A, or 84815A peak power sensors |
| |
|
reseller, reseller channel development, channel development, reseller development, distribution,
distribution management, managment, telemarketing, marketing, marketing surveys, surveys, leads,
lead qualification, seminar, seminar recruitment, business development
|
©1999-2002 [fill in company name] All Rights Reserved |
contact
webmaster
| powered by
corezon
|
|
All logos and trademarks are properties of their respective companies. Product price,
specification, warranty and availability subject to change without notice.
|
|
|